Back to repair cases
San Leandro LG LG Refrigerator Model LFC21770ST Not Cooling

LG Freezer Not Cooling in San Leandro: Restriction Cleared and R-134a Recharge

An LG LFC21770ST freezer was not cooling in San Leandro and its compressor reached about 170°F. We cleared a restriction and recharged the R-134a system.

New customer offer 5% OFF LABOR

Mention this repair story when scheduling service.

Cannot be combined with other offers.
LG Refrigerator Sealed System Repair in San Leandro | Model LFC21770ST repair photo

Repair Summary

City
San Leandro, CA
Appliance
LG refrigerator and freezer, model LFC21770ST, serial 807KRLR00024
Replacement Parts
Refrigeration filter-drier and R-134a refrigerant during sealed-system service
Problem
The freezer was not freezing properly and the refrigerator temperature was too high.
Cause
A restriction in the sealed refrigeration system reduced refrigerant circulation and forced the compressor to run excessively hot.
Repair
We opened and serviced the sealed system, corrected the restriction, installed the filter-drier, evacuated the system, and recharged it with R-134a refrigerant.
Result
After approximately 90 minutes of sealed-system work, the refrigerator resumed normal cooling

Location: San Leandro, CA

Appliance: LG refrigerator and freezer, model LFC21770ST, serial 807KRLR00024

Replacement parts used: Refrigeration filter-drier and R-134a refrigerant during sealed-system service. The filter-drier part number was not visible in the service photos.

Customer complaint: The freezer was not freezing properly and the refrigerator temperature was too high.

Cause: A restriction in the sealed refrigeration system reduced refrigerant circulation and forced the compressor to run excessively hot.

Repair completed: We opened and serviced the sealed system, corrected the restriction, installed the filter-drier, evacuated the system, and recharged it with R-134a refrigerant.

Result: After approximately 90 minutes of sealed-system work, the refrigerator resumed normal cooling. The customer was satisfied with the repair.

LG freezer not cooling diagnosis in San Leandro

The customer in San Leandro called because the freezer was no longer freezing food properly. During diagnosis, we confirmed that the temperature inside the refrigerator was too high. At the rear of the appliance, the compressor surface temperature was approximately 170 degrees Fahrenheit.

A compressor running this hot while the cabinet remains warm indicates that the refrigeration system needs immediate diagnosis. In this case, the measurements and system behavior pointed to a sealed-system restriction that was limiting refrigerant circulation.

LG LFC21770ST refrigerator prepared for sealed system repair in San Leandro CA

Compressor and refrigerant information

The compressor label identified an Embraco EGX 80HLC compressor designed for R-134a refrigerant, 115-127V and 60Hz. Recording these details is important before sealed-system service because the refrigerant type, tools, pressure readings, and charging process must match the appliance.

The refrigerator data label identified the appliance as LG model LFC21770ST, serial 807KRLR00024. The exact model number was used to document this San Leandro repair case.

Embraco EGX 80HLC R-134a compressor on LG refrigerator in San Leandro CA LG refrigerator model LFC21770ST serial 807KRLR00024 label in San Leandro CA

Clearing the sealed-system restriction

We explained the sealed-system diagnosis and repair plan to the customer. After approval, we corrected the restriction and serviced the filter-drier area. A filter-drier helps capture moisture and contaminants in the refrigerant circuit, which is especially important when the system has been opened for repair.

This work requires refrigeration tools and proper handling of pressurized refrigerant. It is not the same as replacing an accessible electrical component and should be performed by a qualified appliance refrigeration technician.

Copper filter-drier installed during LG refrigerator sealed system repair in San Leandro

Evacuation and R-134a recharge

After correcting the restriction and completing the sealed-system connections, we evacuated the refrigeration circuit and recharged it with the correct R-134a refrigerant. The service manifold and hoses were used to monitor the system during the procedure.

The complete repair took approximately one and a half hours. After service, the compressor and refrigeration circuit returned to normal operation and the refrigerator began cooling correctly again.

R-134a manifold gauges used to recharge LG refrigerator in San Leandro CA

Repair video

This short video shows the same LG refrigerator sealed-system repair and R-134a service completed in San Leandro.

Final result

After the restriction was cleared and the sealed system was recharged, the LG refrigerator and freezer operated normally. The freezer returned to proper cooling, and the customer was happy with the completed repair.

If a freezer is warm while the compressor runs constantly or becomes unusually hot, the cause may be a sealed-system restriction, refrigerant loss, compressor problem, airflow issue, fan failure, or control fault. Accurate diagnosis is necessary before any refrigerant work is performed.